Parts - Sensors - Inductive - 2-wire DC tubular quick disconnect
 
Images:
Documents:
ETK Number: S-SIN-2DC-IFM-15835
 
Manufacturer: IFM Efector
 
Model: IIS206
 
 
 
 
Price: Request a Quote
 
Comment: IIKC015BASKG/M/US Metal thread M30 x 1.5 Quick disconnect Operation as 3-wire or 2-wire possible Increased sensing range Optical setting aid (2 LED) gold-plated contacts Sensing range 15mm [f] flush mountable
 
Description: In automated processes, sensors are used to provide signals on positions and limits, serve as pulse pick-ups for counting tasks or for monitoring rotational speed. Inductive proximity sensors are indispensable for these types of applications. As compared to mechanical devices, they offer ideal features:non-contact detection of all metals, high switching frequencies, accuracy, and durability in the most aggressive environments. They are insensitive to vibration, dust, and moisture.

  • Extended sensing range reduces failures from mechanical damage
  • Sensors operate as PNP or NPN for versatile wiring solutions
  • A variety of housing length options to meet application needs
  • Four LEDs provide 360-degree visibility
  • Industry standard M12 Micro DC connector


Electrical design: 3-wire DC PNP; 2-wire DC PNP/NPN

Output: normally open

Operating voltage [V]: 10...30 DC

Current rating [mA]: 100

Minimum load current [mA]: 2 *)

Short-circuit protection: Yes (non-latching)

Reverse polarity protection: yes

overload protection: yes

Voltage drop [V]: < 2.5

Leakage current [mA]: < 0.6 *)

Current consumption [mA]: < 10 (24 V)

Real sensing range [mm]: 15 ± 10 %

Operating distance [mm]: 0...12.1

Switch-point drift [% / Sr]: -10...10

Hysteresis [% / Sr]: 3...15

Switching frequency [Hz]: 100

Correction factors: mild steel = 1 / stainless steel approx. 0.7 / brass approx. 0.5 / Al approx. 0.4 / Cu approx. 0.3

Operating temperature [°C]: -25...70

Protection: IP 67

EMC: EN 61000-4-2 ESD: 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: 10 V/m (80...1000 MHz)
EN 61000-4-4 Burst: 2 kV
EN 61000-4-6 HF conducted: 10 V (0.15...80 MHz)
EN 55011: class B

Housing material: brass Optalloy-plated; active face: PBT

Function display:
Switching status LED: yellow (4 x 90°)
Setting aid LED: red

Connection: M12 connector; gold-plated contacts

Remarks: *) only in 2-wire operation

Accessories (included): 2 lock nuts
 
 
 